345 research outputs found

    Decay Process for Three - Species Reaction - Diffusion System

    Full text link
    We propose the deterministic rate equation of three-species in the reaction - diffusion system. For this case, our purpose is to carry out the decay process in our three-species reaction-diffusion model of the form A+B+CDA+B+C\to D. The particle density and the global reaction rate are also shown analytically and numerically on a two-dimensional square lattice with the periodic boundary conditions. Especially, the crossover of the global reaction rate is discussed in both early-time and long-time regimes.Comment: 6 pages, 3 figures, Late

    Contemporary outcomes of vertebral artery injury

    Get PDF
    ObjectiveVertebral artery injury (VAI) associated with cervical trauma is being increasingly recognized with more aggressive screening. Disparate results from previous literature have led to uncertainty of the significance, natural history, and optimal therapy for VAI.MethodsTo understand the natural history and treatment outcomes from our experience, we performed a retrospective, single-center review from a level I trauma center for the previous 10 years of all VAI. Injuries were identified from search of an administrative trauma database, a resident-run working database, and all radiology dictations for the same period. All VAI were classified according to segmental involvement, Denver grading scale, and laterality. Analysis of associated injuries, demographics, neurologic outcome, mortality, length of stay, treatment plan, and follow-up imaging was also performed.ResultsFifty-one patients with VAI were identified from 2001 to 2011 from a total of 36,942 trauma admissions (0.13% incidence). Associated injuries were significant with an average New Injury Severity Score of 29.6. Penetrating trauma occurred in 14%. Cervical spine fracture was present in 88% with VAI. Diagnosis was obtained with computed tomographic angiography (CTA) in 95%. Screening was prompted by injury pattern or high-risk mechanism in all cases. Injuries classified according to the Denver grading scale were grade I = 24%, grade II = 35%, grade III = 4%, grade IV = 35%, and grade V = 2%. Distribution across segments included V1 = 18%, V2 = 67%, V3 = 31%, and V4 = 6%. Only one posterior circulation stroke was attributable to VAI. Overall mortality was 8%, with each mortality being associated with significant other organ injuries. Treatment rendered for VAI was antiplatelet therapy (50%), observation (31%), warfarin (17%), and stent (2%). There were no significant differences between treatment groups on any variable with the exception of body mass index (P = .047). Follow-up was obtained for 13% (n = 6) of survivors. The CTA demonstrated injury stability in four patients and resolution in two patients. Accuracy of the administrative trauma database was 53% compared with 96% for the resident-run working database.ConclusionsNeurologic sequelae attributable to VAI were rare. Grade of VAI or vertebral artery segment did not correlate with morbidity. We did not observe any differences in short-term outcomes between systemic anticoagulation and antiplatelet therapy. Of those patients seen at follow-up, injury resolution or stability was documented by CTA. A conservative approach with either observation or antithrombotic therapy is suggested. If the natural history of VAI includes a very low stroke rate, then therapies with a lower therapeutic index, such as systemic anticoagulation, in the severely injured trauma patient are not supported. Our search strategy urges awareness of the limitations of administrative databases for retrospective vascular study

    Pharmacokinetics and tumor dynamics of the nanoparticle IT-101 from PET imaging and tumor histological measurements

    Get PDF
    IT-101, a cyclodextrin polymer-based nanoparticle containing camptothecin, is in clinical development for the treatment of cancer. Multiorgan pharmacokinetics and accumulation in tumor tissue of IT-101 is investigated by using PET. IT-101 is modified through the attachment of a 1,4,7,10-tetraazacyclododecane-1,4,7-Tris-acetic acid ligand to bind ^(64)Cu^(2+). This modification does not affect the particle size and minimally affects the surface charge of the resulting nanoparticles. PET data from ^(64)Cu-labeled IT-101 are used to quantify the in vivo biodistribution in mice bearing Neuro2A s.c. tumors. The ^(64)Cu-labeled IT-101 displays a biphasic plasma elimination. Approximately 8% of the injected dose is rapidly cleared as a low-molecular-weight fraction through the kidneys. The remaining material circulates in plasma with a terminal half-life of 13.3 h. Steadily increasing concentrations, up to 11% injected dose per cm^3, are observed in the tumor over 24 h, higher than any other tissue at that time. A 3-compartment model is used to determine vascular permeability and nanoparticle retention in tumors, and is able to accurately represent the experimental data. The calculated tumor vascular permeability indicates that the majority of nanoparticles stay intact in circulation and do not disassemble into individual polymer strands. A key assumption to modeling the tumor dynamics is that there is a “sink” for the nanoparticles within the tumor. Histological measurements using confocal microscopy show that IT-101 localizes within tumor cells and provides the sink in the tumor for the nanoparticles

    Survival outcomes and clinical benefit in patients with acute myeloid leukemia treated with glasdegib and low-dose cytarabine according to response to therapy

    Get PDF
    Background: The phase 2 BRIGHT AML 1003 trial evaluated efficacy and safety of glasdegib + low-dose cytarabine (LDAC) in patients with acute myeloid leukemia ineligible for intensive chemotherapy. The multicenter, open-label study randomized patients to receive glasdegib + LDAC (n = 78) or LDAC alone (n = 38). The rate of complete remission (CR) was 19.2% in the glasdegib + LDAC arm versus 2.6% in the LDAC arm (P = 0.015). Methods: This post hoc analysis determines whether the clinical benefits of glasdegib are restricted to patients who achieve CR, or if they extend to those who do not achieve CR. Results: In patients who did not achieve CR, the addition of glasdegib to LDAC improved overall survival (OS) versus LDAC alone (hazard ratio = 0.63 [95% confidence interval, 0.41-0.98]; P = 0.0182; median OS, 5.0 vs 4.1 months). Additionally, more patients receiving glasdegib + LDAC achieved durable recovery of absolute neutrophil count (≥ 1000/μl, 45.6% vs 35.5%), hemoglobin (≥ 9 g/dl, 54.4% vs 38.7%), and platelets (≥ 100,000/μl, 29.8% vs 9.7%). Transfusion independence was achieved by 15.0% and 2.9% of patients receiving glasdegib + LDAC and LDAC alone, respectively. Conclusions: Collectively, these data suggest that there are clinical benefits with glasdegib in the absence of CR. Trial registration: ClinicalTrials.gov NCT01546038 (March 7, 2012

    The HADES Tracking System

    Full text link
    The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in total about 30 square meter of active area. Low multiple scattering in the in total four planes of drift chambers before and after the magnetic field is ensured by using helium-based gas mixtures and aluminum cathode and field wires. First in-beam performance results are contrasted with expectations from simulations. Emphasis is placed on the energy loss information, exploring its relevance regarding track recognition.Comment: 6 pages, 4 figures, presented at the 10th Vienna Conference on Instrumentation, Vienna, February 2004, to be published in NIM A (special issue

    Impact of Spacecraft Shielding on Direct Ionization Soft Error Rates for Sub-130 nm Technologies

    Get PDF
    We use ray tracing software to model various levels of spacecraft shielding complexity and energy deposition pulse height analysis to study how it affects the direct ionization soft error rate of microelectronic components in space. The analysis incorporates the galactic cosmic ray background, trapped proton, and solar heavy ion environments as well as the October 1989 and July 2000 solar particle events

    Synthesis of Fluorine-18 Functionalized Nanoparticles for use as in vivo Molecular Imaging Agents

    Get PDF
    Nanoparticles containing fluorine-18 were prepared from block copolymers made by ring opening metathesis polymerization (ROMP). Using the fast initiating ruthenium metathesis catalyst (H_2IMes)(pyr)_2(Cl)_2Ru=CHPh, low polydispersity amphiphilic block copolymers were prepared from a cinnamoyl-containing hydrophobic norbornene monomer and a mesyl-terminated PEG-containing hydrophilic norbornene monomer. Self-assembly into micelles and subsequent cross-linking of the micelle cores by light-activated dimerization of the cinnamoyl groups yielded stable nanoparticles. Incorporation of fluorine-18 was achieved by nucleophilic displacement of the mesylates by the radioactive fluoride ion with 31% incorporation of radioactivity. The resulting positron-emitting nanoparticles are to be used as in vivo molecular imaging agents for use in tumor imaging

    The High-Acceptance Dielectron Spectrometer HADES

    Get PDF
    HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion induced collisions. Its main features include a ring imaging gas Cherenkov detector for electron-hadron discrimination, a tracking system consisting of a set of 6 superconducting coils producing a toroidal field and drift chambers and a multiplicity and electron trigger array for additional electron-hadron discrimination and event characterization. A two-stage trigger system enhances events containing electrons. The physics program is focused on the investigation of hadron properties in nuclei and in the hot and dense hadronic matter. The detector system is characterized by an 85% azimuthal coverage over a polar angle interval from 18 to 85 degree, a single electron efficiency of 50% and a vector meson mass resolution of 2.5%. Identification of pions, kaons and protons is achieved combining time-of-flight and energy loss measurements over a large momentum range. This paper describes the main features and the performance of the detector system
    corecore